5.3001.2 Ductwork and Termination Design

Topic: 
Forced Air
Subtopic: 
Design
Desired Outcome: 
Efficient air flow to all rooms ensured by proper ductwork
TitleSpecification(s)Objective(s)
5.3001.2a
Duct design

Duct design will be performed in accordance with ANSI ANSI American National Standards Institute, www.ansi.org / ACCA ACCA Air Conditioning Contractors of America, www.acca.org Manual D and manufacturer specifications

Maximize air flow

5.3001.2b
Termination design

Termination design will be performed in accordance with ANSI ANSI American National Standards Institute, www.ansi.org / ACCA ACCA Air Conditioning Contractors of America, www.acca.org Manual T and manufacturer specifications

Maximize air flow

Ensure occupant comfort

5.3001.2c
Air filtration

New central forced air HVAC HVAC Heating, ventilation, and air conditioning systems will have minimum MERV MERV Minimum efficiency reporting value 6 filtration with no air bypass around the filters

Particle removal to protect equipment and help maintain indoor air quality