Stand-Alone Timers

Detail ID 7.0104.2
Topic
Plug Load
Subtopic
Lighting Controls
Desired Outcome

Reduce lighting run time without compromising required lighting levels, or safety

SF Single Family Site-Built Housing
MH Manufactured Housing
MF Multifamily Housing

Specifications

  • SF
  • MH
  • MF
Specification Objective

Select timer that:

is compatible with existing wiring and lighting

is UL approved and listed for the installed location

has at least 10 hours of battery backup time

has at least two programmable schedules

has an appropriate manual override

Safe, effective, and reliable timer selection

  • SF
  • MH
  • MF
Specification Objective

Install timer in accordance with NFPA 70 and manufacturer specifications, in a secure location, and in location appropriate enclosure (e.g., weatherproof)

Do not install timers for egress lighting required by NFPA 101

Safe, secure, and proper installation

  • SF
  • MH
  • MF
Specification Objective

Set timer to turn off exterior fixtures when there is sufficient daylight (civil twilight) or when lighting is no longer needed at night per ASHRAE 90.1 or 90.2

Set timer to turn off interior fixtures when light is no longer needed in the space

Lights on when required

  • SF
  • MH
  • MF
Specification Objective

Provide occupants/owners with user's manual, warranty information, installation instructions, and installer contact information

Manufacturer supplied information available to occupant

Previous Detail:
Occupancy Sensors
View Sub-Topic:
Lighting Controls
Next Detail:
Motion Control Sensors