Leak-free and safe installation of water saving devices without affecting performance
Specifications
- SF
- MH
- MF
Specification | Objective |
---|---|
Verify current plumbing infrastructure is sufficient to support the installation(s) and water is free of visible debris that may clog the equipment |
Verify adequacy of plumbing and water source |
- SF
- MH
- MF
Specification | Objective |
---|---|
Select showerheads rated for 2.5 gallons per minute (GPM) or less that include an antiscald valve If multiple heads are provided in a shower stall, the total flow rate may not exceed 2.5 GPM Select features that meet any special needs of the occupant (e.g., shut off, swivel, handheld showers) Select aerators with a flow rate of 2.2 GPM or less |
Select appropriate low-flow devices |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install equipment in accordance with manufacturer specifications and applicable building code Install low-flow devices using a non-hardening thread sealant (i.e., thread tape) |
Safe and proper installation that is serviceable |
- SF
- MH
- MF
Specification | Objective |
---|---|
Permanently remove equipment from job site and recycle or dispose of removed equipment and refrigerant in accordance with local and federal law (e.g., EPA Section 608 of Clean Air Act of 1990) Permanently decommission old equipment |
Old equipment is permanently removed from service, protect the environment, and comply with regulation |
- SF
- MH
- MF
Specification | Objective |
---|---|
Provide occupants/owners with user's manual, warranty information, installation instructions, and installer contact information |
Manufacturer supplied information available to occupant |