Safely reduce thermal loss and prevent freezing of water distribution piping
Specifications
- SF
- MH
- MF
Specification | Objective |
---|---|
Confirm sufficient clearance exists between pipes and heat-producing devices (e.g., combustion venting) |
Verify pipes can be safely insulated |
- SF
- MH
- MF
Specification | Objective |
---|---|
Select insulation that: is a minimum of R-3 is a vapor retarder is the correct interior diameter to match pipes is UV-protected if installed outside |
Select durable and correctly sized pipe insulation |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install insulation without gaps Do not install insulation around pumps (i.e., prevent overheating) Seal all pipe insulation seams, joints, connections with tape, tie straps, or other independent means (i.e., manufactured adhesive seam seal is not sufficient) |
Safe, continuous, and durable installation |
- SF
- MH
- MF
Specification | Objective |
---|---|
Maintain a minimum clearance of 6" between combustible pipe insulation and fuel-fired water heater draft hood and/or single wall metal vent materials |
Prevent a fire hazard |