Specification History
SWS Version | Created | Specification ID | Title | Specification | Objective | Supporting Materials | Rationale | Status |
---|---|---|---|---|---|---|---|---|
Version 2025 | 22/09/2023 - 10:08 | 4.0202.6b | Material selection | Select insulation that has a flame spread and smoke development index of 75/450 or less when tested in accordance with ASTM E84 or UL 723 Insulation should be low expansion foam that does not contain formaldehyde |
Select safe materials |
Not all injected foams are formaldehyde based and adding a requirement that the product not contain formaldehyde and be low expansion foam variety will improve the safety and durability of installations. Since the material specification includes new language, the objective needs to be changed slightly to better align. | Red Line | |
Version 2020 | 14/08/2020 - 14:24 | 4.0202.6b | Material selection | Select insulation that has a flame spread and smoke development index of 75/450 or less when tested in accordance with ASTM E84 or UL 723 |
Select fire safe materials |
Black Line | ||
Version 2020 | 14/08/2020 - 14:24 | 4.0202.6b | Material selection | Select insulation that has a flame spread and smoke development index of 75/450 or less when tested in accordance with ASTM E84 or UL 723 |
Select fire safe materials |
Black Line |