Specification History
SWS Version | Created | Specification ID | Title | Specification | Objective | Supporting Materials | Rationale | Status |
---|---|---|---|---|---|---|---|---|
Version 2020 | 14/08/2020 - 14:24 | 4.0301.9e | Installation | Apply SPF to prescribed R-value to bottom side of floor deck and top of support beams using a pass thickness maximum as indicated by manufacturer specifications Install to a thickness of least a class I vapor retarder or have at least a class I vapor retarder coating or covering in direct contact with the underside of the SPF |
Continuous pressure and thermal boundary that prevents moisture vapor movement |
Black Line | ||
Version 2020 | 14/08/2020 - 14:24 | 4.0301.9e | Installation | Apply SPF to prescribed R-value to bottom side of floor deck and top of support beams using a pass thickness maximum as indicated by manufacturer specifications Install to a thickness of least a class I vapor retarder or have at least a class I vapor retarder coating or covering in direct contact with the underside of the SPF |
Continuous pressure and thermal boundary that prevents moisture vapor movement |
Black Line |