Specification History
SWS Version | Created | Specification ID | Title | Specification | Objective | Supporting Materials | Rationale | Status |
---|---|---|---|---|---|---|---|---|
Version 2020 | 14/08/2020 - 14:24 | 4.0388.1a | Pre-work qualifications | Verify that installation area is free of: active water leaks, fuel leaks (i.e., gas, oil, propane), and pest intrusions uncovered electrical junctions improperly terminated devices (ventilation fans, dryers, plumbing stacks, condensate lines, combustion appliance flues/chimneys, etc.) unshielded high-temperature devices (non-IC rated recessed lights, chimneys, flues, vents, etc.) unless they are zero clearance devices Verify that installation area is intact and structurally sound Verify that all plumbing is within the thermal boundary, or insulated appropriately Verify an appropriate class I vapor retarder is installed between the ground and the floor assembly |
Space safe and prepared for insulation |
Black Line | ||
Version 2020 | 14/08/2020 - 14:24 | 4.0388.1a | Pre-work qualifications | Verify that installation area is free of: active water leaks, fuel leaks (i.e., gas, oil, propane), and pest intrusions uncovered electrical junctions improperly terminated devices (ventilation fans, dryers, plumbing stacks, condensate lines, combustion appliance flues/chimneys, etc.) unshielded high-temperature devices (non-IC rated recessed lights, chimneys, flues, vents, etc.) unless they are zero clearance devices Verify that installation area is intact and structurally sound Verify that all plumbing is within the thermal boundary, or insulated appropriately Verify an appropriate class I vapor retarder is installed between the ground and the floor assembly |
Space safe and prepared for insulation |
Black Line |