Specification History
SWS Version | Created | Specification ID | Title | Specification | Objective | Supporting Materials | Rationale | Status |
---|---|---|---|---|---|---|---|---|
Version 2025 | 24/09/2023 - 17:16 | 4.0402.1b | Material selection | Select insulation that: has a flame spread/smoke development index of 25/450 or less when tested in accordance with ASTM E 84 or UL 723 is, or include a facing that is, a class II vapor retarder is not water absorbent , basic_html |
Select fire safe and hydrophobic materials , basic_html |
Regardless of Appendix A which doesn't specify where the insulation types are to be installed, this is about preventing moist air from moving from inside a conditioned space to the exterior surface and condensing. Previously, the committees debated whether or not any drying to the inside was desirable and determined the answer was no. The other specs mentioned in the justification are relating to conditioned basements, which typically have more connection to the main body of the house, and are better conditioned. | Red Line | |
Version 2025 | 24/09/2023 - 17:16 | 4.0402.1b | Material selection | Select insulation that: has a flame spread/smoke development index of 25/450 or less when tested in accordance with ASTM E 84 or UL 723 is, or include a facing that is, a class II vapor retarder is not water absorbent |
Select fire safe and moisture resistant materials |
Regardless of Appendix A which doesn't specify where the insulation types are to be installed, this is about preventing moist air from moving from inside a conditioned space to the exterior surface and condensing. Previously, the committees debated whether or not any drying to the inside was desirable and determined the answer was no. The other specs mentioned in the justification are relating to conditioned basements, which typically have more connection to the main body of the house, and are better conditioned. | Red Line | |
Version 2020 | 14/08/2020 - 14:25 | 4.0402.1b | Material selection | Select insulation that: has a flame spread/smoke development index of 25/450 or less when tested in accordance with ASTM E 84 or UL 723 is, or include a facing that is, a class II vapor retarder is non-absorbent |
Select fire safe and moisture resistant materials |
Black Line | ||
Version 2020 | 14/08/2020 - 14:25 | 4.0402.1b | Material selection | Select insulation that: has a flame spread/smoke development index of 25/450 or less when tested in accordance with ASTM E 84 or UL 723 is, or include a facing that is, a class II vapor retarder is non-absorbent |
Select fire safe and moisture resistant materials |
Black Line |