Specification History

SWS Version Created Specification ID Title Specification Objective Supporting Materials Rationale Status
Version 2020 14/08/2020 - 14:25 5.0104.1o Room pressure balancing

Room-to-room pressure differences shall not exceed 3 pascals with the air handler running

Install appropriate means of pressure balancing if necessary (e.g., transfer grilles, jumper ducts, individual room returns)

Unrestricted air flow, minimize shell leakage caused by duct system, prevent interference with combustion appliance function

Black Line
Version 2020 14/08/2020 - 14:25 5.0104.1o Room pressure balancing

Room-to-room pressure differences shall not exceed 3 pascals with the air handler running

Install appropriate means of pressure balancing if necessary (e.g., transfer grilles, jumper ducts, individual room returns)

Unrestricted air flow, minimize shell leakage caused by duct system, prevent interference with combustion appliance function

Black Line