Specification History
SWS Version | Created | Specification ID | Title | Specification | Objective | Supporting Materials | Rationale | Status |
---|---|---|---|---|---|---|---|---|
Version 2020 | 14/08/2020 - 14:25 | 5.0105.5b | Boot construction | Build boot 1/8" smaller in width than the opening in the main duct trunk and a minimum of 2" longer than the distance between the top of the duct trunk and the top of the subfloor Bend a 1/2" wide outward facing lip on all sides of the top facing end of the boot Cut 1" wide tabs in the bottom 1-1/2" of the sheet metal boot that will fold under into the duct trunk |
Boot fits in trunk and allows firm connection to both subfloor and trunk line |
Black Line | ||
Version 2020 | 14/08/2020 - 14:25 | 5.0105.5b | Boot construction | Build boot 1/8" smaller in width than the opening in the main duct trunk and a minimum of 2" longer than the distance between the top of the duct trunk and the top of the subfloor Bend a 1/2" wide outward facing lip on all sides of the top facing end of the boot Cut 1" wide tabs in the bottom 1-1/2" of the sheet metal boot that will fold under into the duct trunk |
Boot fits in trunk and allows firm connection to both subfloor and trunk line |
Black Line |