SWS Version | Created | Specification ID | Title | Specification | Objective | Supporting Materials | Rationale | Status |
---|---|---|---|---|---|---|---|---|
Version 2020 | 14/08/2020 - 14:26 | 6.0101.1b | Design and configuration | Install ventilation ducts as short, straight, smooth and fully extended as possible considering the following: Vent termination location; Amount of space for duct run; Roof condition, type, and access (e.g., metal, shingle, bowstring, flat) Choose duct diameter that is equal to or greater than the exhaust fan outlet Slope duct downwards towards the termination when possible Install flexible duct so the radius at the centerline of any turn is no less than one duct diameter |
Smooth and direct air movement |
Black Line | ||
Version 2020 | 14/08/2020 - 14:26 | 6.0101.1b | Design and configuration | Install ventilation ducts as short, straight, smooth and fully extended as possible considering the following: Vent termination location; Amount of space for duct run; Roof condition, type, and access (e.g., metal, shingle, bowstring, flat) Choose duct diameter that is equal to or greater than the exhaust fan outlet Slope duct downwards towards the termination when possible Install flexible duct so the radius at the centerline of any turn is no less than one duct diameter |
Smooth and direct air movement |
Black Line |