Version 2020 | 14/08/2020 - 14:27 | 6.0301.1a | Pre-work qualifications | Existing forced air system duct leakage to outside will be less than 10% of the air handler flow when measured at 25 pascals with reference to outside Any portion of the return located inside a combustion appliance zone will be sealed |
Prevent contamination through duct leakage |
Black Line | ||
Version 2020 | 14/08/2020 - 14:27 | 6.0301.1a | Pre-work qualifications | Existing forced air system duct leakage to outside will be less than 10% of the air handler flow when measured at 25 pascals with reference to outside Any portion of the return located inside a combustion appliance zone will be sealed |
Prevent contamination through duct leakage |