Specification History
SWS Version | Created | Specification ID | Title | Specification | Objective | Supporting Materials | Rationale | Status |
---|---|---|---|---|---|---|---|---|
Version 2020 | 14/08/2020 - 14:27 | 6.0305.1b | Sizing | Size the system with enough capacity to handle humidity from outside air ventilation and internal gains Maintain humidity levels inside the home at less than 60% relative humidity For residential applications, follow ASHRAE 62.2 and local code requirements to identify design airflow rates within dwelling units For commercial applications, follow local code requirements and/or ASHRAE 62.1 requirements |
Ensure system ability to maintain the desired humidity |
Black Line | ||
Version 2020 | 14/08/2020 - 14:27 | 6.0305.1b | Sizing | Size the system with enough capacity to handle humidity from outside air ventilation and internal gains Maintain humidity levels inside the home at less than 60% relative humidity For residential applications, follow ASHRAE 62.2 and local code requirements to identify design airflow rates within dwelling units For commercial applications, follow local code requirements and/or ASHRAE 62.1 requirements |
Ensure system ability to maintain the desired humidity |
Black Line |