SWS Version | Created | Specification ID | Title | Specification | Objective | Supporting Materials | Rationale | Status |
---|---|---|---|---|---|---|---|---|
Version 2020 | 14/08/2020 - 14:28 | 7.0301.3d | Cold/tempered water supply | Plumb the tempered water line (post-drain heat recovery device) as close to the primary fixture as possible (e.g., showerhead); or to fixtures that will have water use concurrent with drain heat recovery (e.g., shower that is supplying the drain water); or to the cold water intake of the water heater |
Minimize heat loss from tempered water |
Black Line | ||
Version 2020 | 14/08/2020 - 14:28 | 7.0301.3d | Cold/tempered water supply | Plumb the tempered water line (post-drain heat recovery device) as close to the primary fixture as possible (e.g., showerhead); or to fixtures that will have water use concurrent with drain heat recovery (e.g., shower that is supplying the drain water); or to the cold water intake of the water heater |
Minimize heat loss from tempered water |
Black Line |