Specification History
SWS Version | Created | Specification ID | Title | Specification | Objective | Supporting Materials | Rationale | Status |
---|---|---|---|---|---|---|---|---|
Version 2020 | 14/08/2020 - 14:28 | 7.0302.4c | Location | Install appliance where it: is protected from freezing is accessible for service will maximize efficient operation of the water heating system will minimize distance between tank and primary hot water outlets does not obstruct building egress or access, as required by applicable code (e.g., NFPA 101) |
Select freeze protected, safe, and accessible location that maximizes operation of the water heating system |
Black Line | ||
Version 2020 | 14/08/2020 - 14:28 | 7.0302.4c | Location | Install appliance where it: is protected from freezing is accessible for service will maximize efficient operation of the water heating system will minimize distance between tank and primary hot water outlets does not obstruct building egress or access, as required by applicable code (e.g., NFPA 101) |
Select freeze protected, safe, and accessible location that maximizes operation of the water heating system |
Black Line |