Specification History
SWS Version | Created | Specification ID | Title | Specification | Objective | Supporting Materials | Rationale | Status |
---|---|---|---|---|---|---|---|---|
Version 2025 | 12/10/2023 - 15:46 | 0.0401.1d | Installation | Install panels to prescribed R-value in compliance with the manufacturer's instructions including: using fasteners of the proper length and material, installing fasteners with correct fastener spacing, and Install panels above grade as per manufacture's specification Seal all insulation seams, joints and connections in each layer with compatible sealant (caulk, tape, mastic, etc.) , basic_html |
Select safe and effective fasteners and sealants that provide secure and weathertight contact with retrofit panels to existing sheathing , basic_html |
Red Line | ||
Version 2025 | 12/10/2023 - 15:46 | 0.0401.1d | Installation | Install panels to prescribed R-value in compliance with the manufacturer's instructions including: using fasteners of the proper length and material, installing fasteners with correct fastener spacing, and Install panels above grade as per manufacture's specification Seal all insulation seams, joints and connections in each layer with compatible sealant (caulk, tape, mastic, etc.) , basic_html |
Select safe and effective fasteners and sealants that provide secure and weathertight contact with retrofit panels to existing sheathing , basic_html |
Red Line | ||
Version 2025 | 12/10/2023 - 15:46 | 0.0401.1d | Installation | Conform with required building codes for panel R-value and installation Determine appropriate panel thickness for optimum cost/benefit and prevention of condensation on warm side of retrofit panel challenging wall details might be resolved with the use of different retrofit panel thicknesses Install panels using fasteners of the proper length and material specified by manufacturer Seal all panel joints and seams must be compatible with extruded polystyrene (EPS) if adhesive or sealant is in contact with EPS, or low-expansion and low volatile organic compound (VOC) spray polyurethane foam may be used to seal gaps or voids, or sealing mastic or panel sealant may be used to seal gaps and voids Existing overhangs must adequately exceed new wall thickness to prevent moisture intrusion All installed panels should be at least 8 inches above grade , basic_html |
Select safe and effective fasteners and sealants that provide secure and weathertight contact with retrofit panels to existing sheathing , basic_html |
Red Line |