Efficient, safe, and compliant heating system installation
Specifications
- SF
- MH
Specification | Objective |
---|---|
Verify that the location chosen for installation will provide sufficient clearances, access, combustion air, and egress as required by the manufacturer's instructions, local codes, and NFPA 211 If conflicts exist between installation standards, the more restrictive provisions will apply |
Sufficient clearance and access |
- SF
- MH
Specification | Objective |
---|---|
Perform residential load calculation in accordance with the current version of ANSI/ACCA Manual J (Residential Load Calculation) or equivalent using interior design temperatures of 70 degrees for heating Calculate load based on post-retrofit dwelling characteristics Calculate combustion air needs in conformance with NFPA 211 and manufacturer requirements In instances where conflicts occur between the code and the manufacturer's installation instructions, the more restrictive provisions will apply |
Properly sized appliance and combustion air intakes |
- SF
- MH
Specification | Objective |
---|---|
Select new unit that: is sized based on manufacturer specifications for the space being heated in its post-weatherization state is EPA-certified and approved for housing type being installed (e.g., Manufactured housing) allows the installation of a dedicated outside air kit |
Safe, effective, and efficient stove is selected |
- SF
- MH
Specification | Objective |
---|---|
Install unit per manufacturer specifications, in accordance with applicable codes and with the current NFPA 211 |
Safe and compliant installation |
- SF
- MH
Specification | Objective |
---|---|
Vent appliance as specified by the manufacturer, local codes, and NFPA 211 If conflicts exist between installation standards, the more restrictive provisions will apply |
Safe and effective venting of combustion by-products |
- SF
- MH
Specification | Objective |
---|---|
Seal all penetrations through the thermal-pressure boundary using appropriate high-temperature materials for the application in compliance with SWS 3.0102.2 |
Reduce air movement around installed unit |
- SF
- MH
Specification | Objective |
---|---|
Permanently decommission old equipment, remove from job site, and recycle or dispose of as required by local codes or regulations |
Old equipment is permanently removed from service, protect the environment, and comply with regulations |
- SF
- MH
Specification | Objective |
---|---|
Provide occupant/owners with user's manual, warranty information, installation instructions, and installer contact information |
Provide occupants and service technicians with instructions |