Sump Pumps

Detail ID 2.0201.4
Topic
Moisture
Subtopic
Drainage
Desired Outcome

Remove bulk water from inside the foundation

SF Single Family Site-Built Housing
MH Manufactured Housing
MF Multifamily Housing

Specifications

  • SF
  • MF
Specification Objective

Select a sump pump that will meet the flow requirements of the home.

Select the most energy efficient pump available, prefer Electrically Commutated Motors (ECM) when possible.

Efficient, properly sized sump pump

  • SF
  • MF
Specification Objective

Install sump pumps per the manufacturer's instructions

Install a check valve to prevent water from reentering the sump well

Properly installed sump pump

  • SF
  • MF
Specification Objective

Discharge sump water a minimum of 10' away from the building

Discharge water away from foundation

  • SF
  • MF
Specification Objective

Verify safe operation and ensure that all operable floats are functioning as intended

Verify correct operation

  • SF
  • MF
Specification Objective

Provide occupant with manufacturer's instructions and all manuals

Ensure occupant is aware of function and maintenance