Detail ID
              2.0401.3
    
    Topic
              Radon
      Subtopic
              Radon Precautionary Measures
      Desired Outcome
            Reduce potential for radon to enter the living space through foundation drain penetrations.
        
        Single Family Site-Built Housing
      
          
        
        Manufactured Housing
      
          
        
        Multifamily Housing
      
      Specifications
| Specification | Objective | 
|---|---|
| Seal around the perimeter of all drain fittings that penetrate a concrete slab using urethane caulk or equivalent sealing material Sealant must not affect the ability of the drain to function and be compatible with the surfaces it contacts | Durable, airtight seals around functional drain fittings | 
| Specification | Objective | 
|---|---|
| Install a one way valve in all untrapped, below grade drain fittings that does not interfere with appropriate drain function | Prevent air infiltration from below grade drains without affecting drain function |