Weathertight window repairs
Specifications
- SF
- MH
- MF
Specification | Objective |
---|---|
Select sealants that: are compatible with their intended surfaces, allow for differential expansion and contraction between dissimilar materials, meet the requirements of the applicable fire safety code (e.g. thermal or ignition barriers), and for use inside the pressure boundary select low volatile organic compound (VOC) sealants that meet independent testing and verification protocols |
Select safe and effective sealants |
- SF
- MH
- MF
Specification | Objective |
---|---|
Select: pest-resistant materials that adequately support applied load and are permanent air barriers, materials that meet the requirements of the applicable fire safety code (e.g. thermal or ignition barriers), and low volatile organic compound (VOC) materials for use inside the pressure boundary that meet independent testing and verification protocols |
Select safe and effective materials |
- SF
- MH
- MF
Specification | Objective |
---|---|
Remove any material from the sealing area that will prevent full adhesion of the selected sealant Remove any material from the sash contact areas that will prevent a tight seal or safe operation |
Surface is clean and ready to accept sealant |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install new sash per manufacturer's instructions Ensure lower sash has a bottom rail bevel that is matched to the bevel of the lower sill Ensure new sash seals against all stops, jambs, existing sash, etc. with no visible gaps Adjust window sash(es) to properly fit the jamb and allow for ease of operation and security |
Weatherproof sash installation |
- SF
- MH
- MF
Specification | Objective |
---|---|
Water-seal and prime new sash if water permeable |
Prevent water damage |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install new or adjust existing sash stops so as to eliminate visible gaps between the stop and window jamb while ensuring sash operates smoothly and securely |
Operable, weathertight sash |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install continuous and complete weather stripping on the bottom of the lower sash where it makes contact with the sill and at the top of the upper sash where it makes contact with the upper part of the window frame while maintaining the operability of the window |
Complete seal of window sash |
- SF
- MH
- MF
Specification | Objective |
---|---|
Adjust existing lock or install new lock so that the rails of the upper and lower sashes are flush and in full contact and no gaps are visible between the sash(es) |
Securely fastened sash |
- SF
- MH
- MF
Specification | Objective |
---|---|
Wrap old sash and any removed materials in plastic and dispose of them off-site in a manner that is compliant with local, state, and federal regulation |
Prevent reuse of old components and protect health and the environment |
- SF
- MH
- MF
Specification | Objective |
---|---|
Verify safe operation and size of egress windows as required by local codes |
Safe egress maintained |