Detail ID
7.0104.5
Topic
Plug Load
Subtopic
Lighting Controls
Desired Outcome
Reduce lighting electrical usage without compromising required lighting levels, or safety
Single Family Site-Built Housing
Manufactured Housing
Multifamily Housing
Specifications
- MF
Specification | Objective |
---|---|
Select control that: is compatible with existing wiring and lighting is UL approved and listed has an appropriate manual override |
Appropriate and safe control selected |
- MF
Specification | Objective |
---|---|
Install switches in accordance with NFPA 70 and manufacturer specifications, in a secure location, and protected from physical damage |
Safe, secure, and proper installation |
- MF
Specification | Objective |
---|---|
Affix permanent labels near the switch location to indicate light level and fixture control |
Operation made clear to occupants |
- MF
Specification | Objective |
---|---|
Provide occupants/owners with user's manual, warranty information, installation instructions, and installer contact information |
Manufacturer supplied information available to occupant |