Safe, compliant, and leak-free system installation that meets the needs of the water consumer without damaging the water system
Specifications
- SF
- MH
- MF
Specification | Objective |
---|---|
Verify current plumbing infrastructure is sufficient to support the installation(s) and is leak-free |
Verify adequacy of plumbing |
- SF
- MH
- MF
Specification | Objective |
---|---|
Select equipment that: provides the treatment level needed in accordance with the National Association of Corrosion Engineers (NACE TPC 7) meets the local water standards and requirements |
Prevent damage to water distribution system and protect water consumer |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install system on a level surface where it is protected from freezing and accessible for service |
Accessible, freeze-protected installation |
- SF
- MH
- MF
Specification | Objective |
---|---|
Provide a level working space not less than 30" in length and 30" in width in front of the control side of the appliance Install appliance and plumbing to allow for inspection, maintenance, and replacement of the appliance and its components, without disturbing other installed equipment, controls, piping, and components, other than what requires repair/replacement |
Ensure the appliance can be easily maintained and replaced |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install system on the cold water side of any water heating system according to manufacturer specifications and applicable codes If conflict exists between code and manufacturer specifications, apply the more restrictive requirement |
Safe, compliant, and durable installation |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install all electrical wiring in compliance with NFPA 70 and manufacturer specifications If conflict exists between code and manufacturer specifications, apply the more restrictive requirement |
Safe and compliant pump installation |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install a cut-off valve for the incoming water line and install bypass piping and valve |
Allow isolation and bypass of conditioning system |
- SF
- MH
- MF
Specification | Objective |
---|---|
Store salts for treating the system in a cool and dry environment, not in contact with the floor, and away from metal solids |
Prevent corrosion |
- SF
- MH
- MF
Specification | Objective |
---|---|
Provide occupants/owners with user's manual, warranty information, installation instructions, and installer contact information as well as a copy of the NACE recommendations |
Manufacturer supplied information available to occupant |