Version 2020 08/14/2020 - 14:23 4.0103.5c General preparation

Prepare the surface according to manufacturers specifications

Install durable backing material over any escape holes in the air barrier and utility junctions that will be covered with SPF

When vented eaves or soffits exist, mechanically fasten insulation baffles in every roof bay that extend above the final insulation level by at least 6"

Install a minimum of one insulation depth marker and one marker every additional 300 ft2 throughout installation area with measurement beginning at the air barrier

Install flags at all utility junctions for future identification and ensure utility junctions remain accessible per local code requirements

Provide depth measurement, and locate junctions for future access