Specification History
SWS Version | Created | Specification ID | Title | Specification | Objective | Supporting Materials | Rationale | Status |
---|---|---|---|---|---|---|---|---|
Version 2020 | 08/14/2020 - 14:23 | 4.0103.7d | Cellulose installation | Install stabilized cellulose (i.e., wet-spray applied) when available If ceiling pitch is less than 6/12, install loose fill cellulose to prescribed R-value without gaps, voids, misalignments, or wind intrusions If ceiling pitch is 6/12 or greater, install baffles of the same height as the insulation perpendicular to slope a maximum of every 6' that prevent loose fill insulation from sliding downward then fill each bay to prescribed R-value without gaps, voids, misalignments, or wind intrusions |
Cellulose insulation remains in place when installed on sloped surface |
Black Line | ||
Version 2020 | 08/14/2020 - 14:23 | 4.0103.7d | Cellulose installation | Install stabilized cellulose (i.e., wet-spray applied) when available If ceiling pitch is less than 6/12, install loose fill cellulose to prescribed R-value without gaps, voids, misalignments, or wind intrusions If ceiling pitch is 6/12 or greater, install baffles of the same height as the insulation perpendicular to slope a maximum of every 6' that prevent loose fill insulation from sliding downward then fill each bay to prescribed R-value without gaps, voids, misalignments, or wind intrusions |
Cellulose insulation remains in place when installed on sloped surface |
Black Line |