Version 2020 08/14/2020 - 14:23 4.0103.7e Fiberglass installation

Install stabilized fiberglass (i.e., wet-spray applied) when available

If ceiling pitch is less than or equal to 6/12, install loose fill fiberglass insulation to prescribed R-value without gaps, voids, misalignments, or wind intrusions

If ceiling pitch is greater than 6/12, loose fill fiberglass insulation may not be used (dense pack fiberglass may be used)

Fiberglass insulation remains in place when installed on sloped surface of appropriate pitch