Specification History
SWS Version | Created | Specification ID | Title | Specification | Objective | Supporting Materials | Rationale | Status |
---|---|---|---|---|---|---|---|---|
Version 2020 | 08/14/2020 - 14:23 | 4.0188.1b | Material selection | Select radiant barrier that has a flame spread and smoke development index of 25/450 or less and backing material for attics used for storage with a smoke development index of 450 or less when tested in accordance with ASTM E84 or UL 723 |
Select fire safe materials |
Black Line | ||
Version 2020 | 08/14/2020 - 14:23 | 4.0188.1b | Material selection | Select radiant barrier that has a flame spread and smoke development index of 25/450 or less and backing material for attics used for storage with a smoke development index of 450 or less when tested in accordance with ASTM E84 or UL 723 |
Select fire safe materials |
Black Line |