Specification History
SWS Version | Created | Specification ID | Title | Specification | Objective | Supporting Materials | Rationale | Status |
---|---|---|---|---|---|---|---|---|
Version 2020 | 08/14/2020 - 14:24 | 4.0202.3b | Material selection | Select insulation that has a flame spread and smoke development index of 25/450 or less when tested in accordance with ASTM E84 or UL 723 Select a poly-encased fiberglass batt or an unfaced fiberglass batt and a flexible class 1 vapor retarder membrane |
Select correct and fire safe materials |
Black Line | ||
Version 2020 | 08/14/2020 - 14:24 | 4.0202.3b | Material selection | Select insulation that has a flame spread and smoke development index of 25/450 or less when tested in accordance with ASTM E84 or UL 723 Select a poly-encased fiberglass batt or an unfaced fiberglass batt and a flexible class 1 vapor retarder membrane |
Select correct and fire safe materials |
Black Line |