Version 2020 08/14/2020 - 14:25 5.0101.1d Heat pump considerations

Connect supplementary heat to second-stage heating terminal in accordance with manufacturer specifications

Install and connect outdoor temperature sensor that is compatible with the thermostat in accordance with manufacturer specifications

Calculate and select an optimum thermal balance point for supplementary heat operation in accordance with ANSI/ACCA Manual S and manufacturer specifications

Prevent supplementary heat operation when heat pump can meet heating load

Black Line
Version 2020 08/14/2020 - 14:25 5.0101.1d Heat pump considerations

Connect supplementary heat to second-stage heating terminal in accordance with manufacturer specifications

Install and connect outdoor temperature sensor that is compatible with the thermostat in accordance with manufacturer specifications

Calculate and select an optimum thermal balance point for supplementary heat operation in accordance with ANSI/ACCA Manual S and manufacturer specifications

Prevent supplementary heat operation when heat pump can meet heating load

Black Line