Specification History
SWS Version | Created | Specification ID | Title | Specification | Objective | Supporting Materials | Rationale | Status |
---|---|---|---|---|---|---|---|---|
Version 2020 | 08/14/2020 - 14:25 | 5.0101.1d | Heat pump considerations | Connect supplementary heat to second-stage heating terminal in accordance with manufacturer specifications Install and connect outdoor temperature sensor that is compatible with the thermostat in accordance with manufacturer specifications Calculate and select an optimum thermal balance point for supplementary heat operation in accordance with ANSI/ACCA Manual S and manufacturer specifications |
Prevent supplementary heat operation when heat pump can meet heating load |
Black Line | ||
Version 2020 | 08/14/2020 - 14:25 | 5.0101.1d | Heat pump considerations | Connect supplementary heat to second-stage heating terminal in accordance with manufacturer specifications Install and connect outdoor temperature sensor that is compatible with the thermostat in accordance with manufacturer specifications Calculate and select an optimum thermal balance point for supplementary heat operation in accordance with ANSI/ACCA Manual S and manufacturer specifications |
Prevent supplementary heat operation when heat pump can meet heating load |
Black Line |