Specification History
SWS Version | Created | Specification ID | Title | Specification | Objective | Supporting Materials | Rationale | Status |
---|---|---|---|---|---|---|---|---|
Version 2020 | 08/14/2020 - 14:25 | 5.0102.1e | Secondary drain pan | Install a secondary drain pan under all condensing appliances installed in or above conditioned space and where water damage may occur to the structure Install an independent condensate drain for the secondary drain pan that drains to a visible termination location Slope drain pan towards the condensate drain |
Prevent water damage to dwelling |
Black Line | ||
Version 2020 | 08/14/2020 - 14:25 | 5.0102.1e | Secondary drain pan | Install a secondary drain pan under all condensing appliances installed in or above conditioned space and where water damage may occur to the structure Install an independent condensate drain for the secondary drain pan that drains to a visible termination location Slope drain pan towards the condensate drain |
Prevent water damage to dwelling |
Black Line |