Specification History
SWS Version | Created | Specification ID | Title | Specification | Objective | Supporting Materials | Rationale | Status |
---|---|---|---|---|---|---|---|---|
Version 2020 | 08/14/2020 - 14:25 | 5.0103.1c | Installation | Install refrigerant lines without kinks, crimps, or excessive bends Route lines in a manner that protects it from damage by workers and occupants Join lines using manufacturer-approved method(s) Install proper filter dryer(s) on all systems Install P-traps on suction line risers that are greater than 10' in height Use manufacturer specifications to determine appropriate lengths and elevations of refrigerant lines between condensing units and indoor coils |
Durable, safe piping that moves appropriate volume of refrigerant and protects compressor functionality |
Black Line | ||
Version 2020 | 08/14/2020 - 14:25 | 5.0103.1c | Installation | Install refrigerant lines without kinks, crimps, or excessive bends Route lines in a manner that protects it from damage by workers and occupants Join lines using manufacturer-approved method(s) Install proper filter dryer(s) on all systems Install P-traps on suction line risers that are greater than 10' in height Use manufacturer specifications to determine appropriate lengths and elevations of refrigerant lines between condensing units and indoor coils |
Durable, safe piping that moves appropriate volume of refrigerant and protects compressor functionality |
Black Line |