Version 2020 08/14/2020 - 14:25 5.0105.3b Duct materials

Use only rigid ducts of 26 gauge or greater for crossover connections in subspaces (i.e., crawlspaces, belly area)

In attics, if sufficient space is not available for rigid duct installation, UL 181 approved flexible duct may be used

Select durable materials that maximize airflow

Black Line
Version 2020 08/14/2020 - 14:25 5.0105.3b Duct materials

Use only rigid ducts of 26 gauge or greater for crossover connections in subspaces (i.e., crawlspaces, belly area)

In attics, if sufficient space is not available for rigid duct installation, UL 181 approved flexible duct may be used

Select durable materials that maximize airflow