Version 2020 | 08/14/2020 - 14:26 | 5.0108.2a | Load calculation | Perform residential load calculation in accordance with the current version of ANSI/ACCA Manual J (Residential Load Calculation) or equivalent using interior design temperatures of 75 degrees for cooling and 70 degrees for heating Perform commercial load calculation in accordance with the current version of ANSI/ACCA Manual N (Commercial Load Calculation) or equivalent using interior design temperatures of 75 degrees for cooling and 70 degrees for heating Room by room load calculations will be performed when installing a new duct system or in retro-commissioning projects Calculated loads based on post-retrofit dwelling characteristics |
Equipment design load calculated correctly for post-retrofit dwelling |
Black Line | ||
Version 2020 | 08/14/2020 - 14:26 | 5.0108.2a | Load calculation | Perform residential load calculation in accordance with the current version of ANSI/ACCA Manual J (Residential Load Calculation) or equivalent using interior design temperatures of 75 degrees for cooling and 70 degrees for heating Perform commercial load calculation in accordance with the current version of ANSI/ACCA Manual N (Commercial Load Calculation) or equivalent using interior design temperatures of 75 degrees for cooling and 70 degrees for heating Room by room load calculations will be performed when installing a new duct system or in retro-commissioning projects Calculated loads based on post-retrofit dwelling characteristics |