SWS Version Created Specification ID Title Specification Objective Supporting Materials Rationale Status
Version 2020 08/14/2020 - 14:26 5.0108.5g Water management

Install a float switch in the pan that is interlocked to the system power to prevent unit from overflowing

Pipe overflow tube to a properly sized sanitary drain or the outdoors and provided with traps as specified by the manufacturer and applicable building code

Install a back-flow preventor on the potable water supply

Prevent water damage, and potable water contamination

Black Line
Version 2020 08/14/2020 - 14:26 5.0108.5g Water management

Install a float switch in the pan that is interlocked to the system power to prevent unit from overflowing

Pipe overflow tube to a properly sized sanitary drain or the outdoors and provided with traps as specified by the manufacturer and applicable building code

Install a back-flow preventor on the potable water supply

Prevent water damage, and potable water contamination

Black Line