Specification History

SWS Version Created Specification ID Title Specification Objective Rationale Status
Version 2025 05/15/2025 - 12:29 6.0202.1a Duct selection

Select dryer transition duct that is no more than 8 feet in total length, and contains no joints

Flexible transition ducts shall be UL 2158A

Rigid transition ducts shall be metal with smooth interior

Transition ducts shall not extend beyond the room in which the appliance is located

Select primary ducts that are rigid, 30-gauge minimum in thickness, non-corrosive, with a smooth interior.

Smooth airflow that does not collect lint

The committee agreed that the original language required additional clarity regarding material selection. The new revised language specifies materials and standards for both transition and primary dryer ducts. This was done to eliminate confusion between duct types. Red Line
Version 2025 04/28/2025 - 16:48 6.0202.1a Duct selection

The transition ducts (flexible or rigid) used to connect the dryer to the primary exhaust duct system shall be UL 2158A approved and less than 8 feet in total length with no joints. 

Select primary dryer ducting material that is 28 gauge metal with a smooth interior

Smooth airflow that does not collect lint

The committee determined the reference to 28 gauge shall remain because the IRC requires 28 gauge or thicker for all dryer vents (M1502.4.1). The committee determined a need to clarify that transition ducts connect the dryer to the primary exhaust duct. Red Line
Version 2025 09/25/2023 - 11:24 6.0202.1a Duct selection

The transition ducts (flexible or rigid) used to connect the dryer to the primary exhaust duct system shall be UL 2158A approved and less than 8 feet in total length with no joints. 

Select primary dryer ducting material that is 28 gauge metal with a smooth interior

Smooth airflow that does not collect lint

The committee determined the reference to 28 gauge shall remain because the IRC requires 28 gauge or thicker for all dryer vents (M1502.4.1). The committee determined a need to clarify that transition ducts connect the dryer to the primary exhaust duct. Red Line
Version 2020 08/14/2020 - 14:27 6.0202.1a Duct selection

Select dryer transition ducting materials that are UL 2158A approved and less than 8 feet in total length with no joints

Select primary dryer ducting material that is 28 gauge metal with a smooth interior

Smooth airflow that does not collect lint

Black Line
Version 2020 08/14/2020 - 14:27 6.0202.1a Duct selection

Select dryer transition ducting materials that are UL 2158A approved and less than 8 feet in total length with no joints

Select primary dryer ducting material that is 28 gauge metal with a smooth interior

Smooth airflow that does not collect lint

Black Line
Version 2020 08/14/2020 - 14:27 6.0202.1a Duct selection

Select dryer transition ducting materials that are UL 2158A approved and less than 8 feet in total length with no joints

Select primary dryer ducting material that is 28 gauge metal with a smooth interior

Smooth airflow that does not collect lint

Black Line