Specification History
SWS Version | Created | Specification ID | Title | Specification | Objective | Supporting Materials | Rationale | Status |
---|---|---|---|---|---|---|---|---|
Version 2020 | 08/14/2020 - 14:22 | 2.0103.1c | Discharge | Install discharge tube of temperature and pressure relief valve so that it: Discharges to a readily observable location either 6 inches or less from the floor or overflow pan or to the outdoors Discharges in a manner that does not cause personal injury or structural damage Flows by gravity and without any trap Is not directly connected to the dwelling drainage system Does not contain any valves or tees, nor end with a threaded connection |
Ensure proper discharge location |
Black Line | ||
Version 2020 | 08/14/2020 - 14:22 | 2.0103.1c | Discharge | Install discharge tube of temperature and pressure relief valve so that it: Discharges to a readily observable location either 6 inches or less from the floor or overflow pan or to the outdoors Discharges in a manner that does not cause personal injury or structural damage Flows by gravity and without any trap Is not directly connected to the dwelling drainage system Does not contain any valves or tees, nor end with a threaded connection |
Ensure proper discharge location |
Black Line |