Version 2020 08/14/2020 - 14:22 2.0202.1e Seams/connections

Overlap seams a minimum of 12" with reverse or upslope lapping technique

For wall to floor connection, install the wall vapor retarder under the ground vapor retarder

Seal all seams and connections to foundations and piers air tight with a durable, compatible, sealant

Mechanically attach ground vapor retarder to foundation and piers where practical

, basic_html

Provide airtight seal for ground vapor retarder

, basic_html
Red Line
Version 2020 08/14/2020 - 14:22 2.0202.1e Seams/connections

Overlap seams a minimum of 12" with reverse or upslope lapping technique

For wall to floor connection, install the wall vapor retarder under the ground vapor retarder

Seal all seams and connections to foundations and piers air tight with a durable, compatible, sealant

Mechanically attach ground vapor retarder to foundation and piers where practical

Provide airtight seal for ground vapor retarder