Specification History

SWS Version Created Specification ID Title Specification Objective Supporting Materials Rationale Status
Version 2020 08/14/2020 - 14:22 3.0105.1f Ductwork

Seal all accessible ductwork joints and connections with UL 181B or 181B-M welds, gaskets, adhesive mastics, or mastic-plus- embedded-fabric systems

Where the same duct system serves any other living space, all supply and return openings in the garage (including intentional openings designed to heat or cool the garage space) must be disconnected, capped with sheet metal using mechanical fasteners, and completely sealed

Prevent ductwork from distributing pollutants

Black Line
Version 2020 08/14/2020 - 14:22 3.0105.1f Ductwork

Seal all accessible ductwork joints and connections with UL 181B or 181B-M welds, gaskets, adhesive mastics, or mastic-plus- embedded-fabric systems

Where the same duct system serves any other living space, all supply and return openings in the garage (including intentional openings designed to heat or cool the garage space) must be disconnected, capped with sheet metal using mechanical fasteners, and completely sealed

Prevent ductwork from distributing pollutants