Detail ID
2.0103.1
Topic
Safety Devices
Subtopic
Water Heating
Desired Outcome
Safely discharge excessive energy (pressure or temperature) from water heating system
Single Family Site-Built Housing
Manufactured Housing
Multifamily Housing
Specifications
- SF
- MH
- MF
Specification | Objective |
---|---|
Temperature and pressure relief valve will be installed in compliance with IRC, HUD code, and according to manufacturer specifications |
Ensure proper installation |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install discharge tube of temperature and pressure relief valve so that it: Discharges to a readily observable location either 6 inches or less from the floor or overflow pan or to the outdoors Discharges in a manner that does not cause personal injury or structural damage Flows by gravity and without any trap Is not directly connected to the dwelling drainage system Does not contain any valves or tees, nor end with a threaded connection |
Ensure proper discharge location |