Reduce pest, wind, and water intrusion while reducing conductive heat loss in floor assembly
Specifications
- SF
- MH
Specification | Objective |
---|---|
Verify that installation area is free of: active water leaks, fuel leaks (i.e., gas, oil, propane), and pest intrusions uncovered electrical junctions improperly terminated devices (ventilation fans, dryers, plumbing stacks, condensate lines, combustion appliance flues/chimneys, etc.) unshielded high-temperature devices (non-IC rated recessed lights, chimneys, flues, vents, etc.) unless they are zero clearance devices Verify that installation area is intact and structurally sound Verify that all plumbing is within the thermal boundary, or insulated appropriately Verify an appropriate class I vapor retarder is installed between the ground and the floor assembly |
Space safe and prepared for insulation |
- SF
- MH
Specification | Objective |
---|---|
Select materials that are corrosion and rot resistant, compatible with existing surfaces, and pest resistant Select materials that are rated for ground contact if they touch the ground |
Select durable and pest-resistant materials |
- SF
- MH
Specification | Objective |
---|---|
Select sealants that: are compatible with their intended surfaces allow for differential expansion and contraction between dissimilar materials meet the requirements of the applicable fire safety code (e.g., thermal or ignition barriers) |
Select durable, safe, and pest-resistant sealants |
- SF
- MH
Specification | Objective |
---|---|
Remove any existing skirting materials Remove any vegetation from installation area |
Installation area free of obstructions |
- SF
- MH
Specification | Objective |
---|---|
Install skirting continuously around the entire perimeter of the conditioned space |
Minimize pests, wind and water intrusion, and freezing of plumbing under dwelling |
- SF
- MH
Specification | Objective |
---|---|
Install support material as needed to adequately support new skirting to prevent failure under wind or snow loads but that allows for expansion, contraction, and frost heaving |
Adequate yet flexible support |
- SF
- MH
Specification | Objective |
---|---|
Mechanically fasten all skirting in accordance with manufacturer's specifications using corrosion resistant materials |
Durable installation |
- SF
- MH
Specification | Objective |
---|---|
Install flashing that directs bulk water away from the dwelling and to outside skirting Seal flashing to dwelling with compatible sealant |
Prevent water from entering foundation space |
- SF
- MH
Specification | Objective |
---|---|
Install skirting that meets the prescribed R-value |
Reduce conductive heat loss through floor assembly |
- SF
- MH
Specification | Objective |
---|---|
Seal all seams, joints, connections, penetrations, etc. in the skirting with compatible sealant Seal all exposed wood (e.g., paint, sealed, treated) Stuff any gaps larger than 1/4" with copper metal mesh or steel wool prior to sealing |
Airtight, pest resistant exterior |
- SF
- MH
Specification | Objective |
---|---|
Post a dated receipt signed by the installer that minimally includes: Installed insulation type, coverage area, installed thickness, and installed R-value |
Comply with 16 CFR 460.17 and document contract compliance |