Detail ID
5.0109.3
Topic
Forced Air
Subtopic
Clean and Tune
Desired Outcome
Evaporators serviced as needed
Single Family Site-Built Housing
Manufactured Housing
Multifamily Housing
Specifications
- SF
- MH
- MF
Specification | Objective |
---|---|
Verify proper function and safety of the following system elements: Drain pan floats, condensate drain line and condensate pump, TXV, temperature sensing bulbs |
Ensure all components function properly, safely, efficiently, and are durable |
- SF
- MH
- MF
Specification | Objective |
---|---|
Clear condensate lines and clean drain pans Verify condensate termination is free of debris and directs water away from the home Clean evaporator coil Repair or replace additional elements as needed |
Replace/clean necessary parts |
- SF
- MH
- MF
Specification | Objective |
---|---|
Post on equipment, or in a conspicuous location, a list of all systems and components inspected, results, and services performed that includes legible service personnel name, contact information, and date of service |
Verify contract completion |