Efficient, safe, and compliant dwelling conditioning that functions as designed
Specifications
- SF
- MF
Specification | Objective |
---|---|
Equipment design load calculated correctly for post-retrofit dwelling |
- SF
- MF
Specification | Objective |
---|---|
Select new unit that: is ENERGY STAR® qualified or equivalent is ducted if conditioning multiple rooms |
Select efficient, corrosion-resistant system that conditions intended area |
- SF
- MF
Specification | Objective |
---|---|
Install unit per manufacturer specifications and in accord with applicable building code Supply air temperature and gas pressure will be within the manufacturer specifications |
Safe and compliant installation |
- SF
- MF
Specification | Objective |
---|---|
Install a wall mounted thermostat that is not directly affected by supply air flow |
Effective and accessible controls |
- SF
- MF
Specification | Objective |
---|---|
Pipe condensate away from the building or to a sanitary drain Insulate condensate drain to a minimum of R-3 if danger of freezing or condensation exists |
Functional condensate drain |
- SF
- MF
Specification | Objective |
---|---|
Before installing unit, seal adjacent framing or cavity if recessed into wall After installation, seal the perimeter with suitable materials Seal all penetrations through the thermal boundary |
Reduce air movement around installed unit or in wall cavity |
- SF
- MF
Specification | Objective |
---|---|
Permanently remove equipment from job site and recycle or dispose of removed equipment and refrigerant in accordance with local and federal law (e.g., EPA Section 608 of Clean Air Act of 1990) Permanently decommission old equipment |
Old equipment is permanently removed from service, protect the environment, and comply with regulation |
- SF
- MF
Specification | Objective |
---|---|
Provide occupants/owners with user's manual, warranty information, installation instructions and installer contact information |
Provide occupants and service technicians with instructions |