Lighting only on when needed without compromising required lighting levels, or safety
Specifications
- SF
- MH
- MF
Specification | Objective |
---|---|
Select sensors that: are compatible with the existing wiring and lighting fixture is UL approved and listed for the installed location |
Select efficient, reliable, and safe lighting control |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install sensor in accordance with NFPA 70 and manufacturer specifications Do not install occupancy sensors in areas accessed for electrical and mechanical maintenance Set controls to match the intended use of the space (i.e., time off setting not too short or too long) |
Safe installation that doesn't compromise service access |
- SF
- MH
- MF
Specification | Objective |
---|---|
Provide occupants/owners with user's manual, warranty information, installation instructions, and installer contact information |
Manufacturer supplied information available to occupant |