Reduce lighting run time without compromising required lighting levels, or safety
Specifications
- SF
- MH
- MF
Specification | Objective |
---|---|
Select sensor that: is compatible with existing wiring and lighting is UL approved and listed for the installed location is location and climate appropriate (e.g., outdoor weatherproof fixture) |
Safe, effective, and reliable sensor selection |
- SF
- MH
- MF
Specification | Objective |
---|---|
Locate sensor where it will minimize false starts |
Reduce unnecessary operation of lighting |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install timer in accordance with NFPA 70 and manufacturer specifications, in a secure location, and protected from physical damage |
Safe, secure, and proper installation |
- SF
- MH
- MF
Specification | Objective |
---|---|
Set controls of motion sensor based on anticipated occupant usage or security needs Set control to turn off lighting if no motion is detected for a maximum of 15 minutes |
Meet lighting needs for area |
- SF
- MH
- MF
Specification | Objective |
---|---|
Provide occupants/owners with user's manual, warranty information, installation instructions, and installer contact information |
Manufacturer supplied information available to occupant |