Specification History
SWS Version | Created | Specification ID | Title | Specification | Objective | Supporting Materials | Rationale | Status |
---|---|---|---|---|---|---|---|---|
Version 2020 | 08/14/2020 - 14:25 | 5.0104.1d | Termination design | Design terminations using ANSI/ACCA Manual T (Air Distribution Basics) Terminations must be capable of delivering air with proper speed and throw of 80-120% of the farthest wall, floor, or ceiling they serve, and must have a noise level less than 30 decibels Return grille gross area will be equal to or larger than return box |
Appropriate level of air mixing, air flow, and occupant comfort |
Black Line | ||
Version 2020 | 08/14/2020 - 14:25 | 5.0104.1d | Termination design | Design terminations using ANSI/ACCA Manual T (Air Distribution Basics) Terminations must be capable of delivering air with proper speed and throw of 80-120% of the farthest wall, floor, or ceiling they serve, and must have a noise level less than 30 decibels Return grille gross area will be equal to or larger than return box |
Appropriate level of air mixing, air flow, and occupant comfort |
Black Line |