Specification History

SWS Version Created Specification ID Title Specification Objective Supporting Materials Rationale Status
Version 2025 09/24/2023 - 17:13 6.0202.1b Venting installation

Vent all clothes dryers to the outdoors, which does not include unconditioned spaces such as attics and crawl spaces that are ventilated with the outdoors

Choose the shortest practical installation path

Install a dryer exhaust duct power ventilator that is listed and labeled to UL 705 for dryer ducts exceeding 35' in equivalent length

Install ducts according to SWS detail for "Ventilation Ducts"

Dryer ducted to outdoors durably and effectively

Interestingly, the IRC has switched the terminology here in the 2021 version (IRC M1502.4.5). They forbid "domestic booster fans", but allow for "domestic exhaust duct power ventilators" that meet UL 705. They also prescriptively limit the length of dryer duct to a maximum of 35 feet TOTAL length though they allow the dryer manufacturer's instructions to supersede this direction which opens the door for the "power ventilators" and longer duct runs. Therefore, we have removed the booster fan requirement and limited the duct length to 35' equivalent maximum. Red Line
Version 2020 08/14/2020 - 14:27 6.0202.1b Venting installation

Vent all clothes dryers to the outdoors, which does not include unconditioned spaces such as attics and crawl spaces that are ventilated with the outdoors

Choose the shortest practical installation path

Install a dryer booster fan that is listed and labeled to UL 705 for dryer ducts exceeding 35' in equivalent length

Install ducts according to SWS detail for "Ventilation Ducts"

Dryer ducted to outdoors durably and effectively

Black Line
Version 2020 08/14/2020 - 14:27 6.0202.1b Venting installation

Vent all clothes dryers to the outdoors, which does not include unconditioned spaces such as attics and crawl spaces that are ventilated with the outdoors

Choose the shortest practical installation path

Install a dryer booster fan that is listed and labeled to UL 705 for dryer ducts exceeding 35' in equivalent length

Install ducts according to SWS detail for "Ventilation Ducts"

Dryer ducted to outdoors durably and effectively

Black Line