Specification History
SWS Version | Created | Specification ID | Title | Specification | Objective | Supporting Materials | Rationale | Status |
---|---|---|---|---|---|---|---|---|
Version 2025 | 09/24/2023 - 17:10 | 7.0302.3c | Location | Install appliance where it: is in a location above the minimum temperature specified by the equipment manufacturer is accessible for service has sufficient volume of air per manufacturer specifications will not affect indoor thermostat readings or blow directly on occupants |
Select indoor, safe, and accessible location with sufficient air volume |
While they "can" be installed in unconditioned spaces, it is not ideal for efficiency purposes. If installed in a basement space that is unintentionally conditioned, it might be fine, but should not be in truly unconditioned spaces like attics or garages, especially in cold climates. Climate would make a difference on this one. Manufacturer will list a temperature. WE should focus on that. Don't install below a temp. that is specified by the equipment manufacturer. Similar to sufficient volume language, go with that for temperature. | Red Line | |
Version 2020 | 08/14/2020 - 14:28 | 7.0302.3c | Location | Install appliance where it: is in conditioned space is accessible for service has sufficient volume of air per manufacturer specifications will not affect indoor thermostat readings or blow directly on occupants |
Select indoor, safe, and accessible location with sufficient air volume |
Black Line | ||
Version 2020 | 08/14/2020 - 14:28 | 7.0302.3c | Location | Install appliance where it: is in conditioned space is accessible for service has sufficient volume of air per manufacturer specifications will not affect indoor thermostat readings or blow directly on occupants |
Select indoor, safe, and accessible location with sufficient air volume |
Black Line |