Minimize ground moisture vapor and soil gas with a durable, effective vapor retarder
Specifications
- SF
- MH
- MF
Specification | Objective |
---|---|
Remove all vegetation from area to be covered Remove all debris that can cause injury or puncture ground vapor retarder (e.g., nails, wood, glass, sheet metal screws, etc.) |
Minimize punctures |
- SF
- MH
- MF
Specification | Objective |
---|---|
Select a 6-mil minimum ground vapor retarder of 0.1 perm or less |
Durable material selected |
- SF
- MH
- MF
Specification | Objective |
---|---|
Cover all exposed soil Extend ground vapor retarder a minimum of 6" up all foundation walls and piers, but do not install in contact with non-treated structural wood Cover all exposed soil
|
Create a continuous ground vapor retarder layer that does not compromise wooden foundation materials Create a continuous ground vapor retarder layer that does not compromise wooden foundation materials |
- SF
- MH
- MF
Specification | Objective |
---|---|
The ground vapor retarder will not interfere with the established drainage pattern (e.g., to sump pits, French drains, etc.) |
Ensure proper drainage |
- SF
- MH
- MF
Specification | Objective |
---|---|
Overlap seams a minimum of 12" with reverse or upslope lapping technique For wall to floor connection, install the wall vapor retarder under the ground vapor retarder |
Keep bulk moisture under ground cover |
- SF
- MH
- MF
Specification | Objective |
---|---|
Fasten ground vapor retarder to ground with durable fasteners or ballast(s) when installed on sloping ground, or space is accessed for routine maintenance or storage |
Prevent movement and uplift of the air barrier and ground moisture barrier |
- SF
- MH
- MF
Specification | Objective |
---|---|
Seal all penetrations in the ground vapor retarder with a compatible sealant
|
Ensure ground vapor retarder is air tight
|
- SF
- MH
- MF
Specification | Objective |
---|---|
Install a durable (minimum of 10-year service life), easily seen sign, sized a minimum of 8.5"x 11" at each access to the space Sign shall minimally include the following items: Warning to prohibit storage of hazardous and flammable materials Caution not to damage the ground vapor retarder, air barrier, insulation, and mechanical components specific to the space Immediate repairs are needed in the case of damage |
Provide essential safety and maintenance information |