Pier and Skirting Foundations - Ground Cover

Detail ID 2.0202.3
Topic
Moisture
Subtopic
Ground Vapor Retarders
Desired Outcome

Minimize ground moisture vapor and soil gas with a durable, effective vapor retarder

SF Single Family Site-Built Housing
MH Manufactured Housing
MF Multifamily Housing

Specifications

Specification Objective

Remove all debris that can cause injury or puncture ground vapor retarder (e.g., nails, glass, sheet metal screws, etc.)

Minimize punctures

Specification Objective

Cover all exposed soil

Extend ground vapor retarder a minimum of 6" up all foundation walls and piers, but do not install in contact with non-treated structural wood

Create a continuous ground vapor retarder layer that does not compromise wooden foundation materials

Specification Objective

Select a 6-mil minimum ground vapor retarder of 0.1 perm or less

Durable material selected

Specification Objective

Overlap seams a minimum of 12" with reverse or upslope lapping technique

For wall to floor connection, install the wall vapor retarder under the ground vapor retarder

Keep bulk moisture under ground cover

Specification Objective

Fasten ground vapor retarder to ground with durable fasteners

Prevent movement of the ground moisture barrier

View Sub-Topic:
Ground Vapor Retarders