Durable, pest-resistant, thermal break between the slab edge and outdoors
Specifications
- SF
- MF
Specification | Objective |
---|---|
Verify all bulk sources of moisture have been directed away from the slab (i.e., gutters, flashing, grading, drainage) Wall sill plate and slab edge penetration air sealing is completed No active pest intrusions exist |
Ensure space can be safely insulated |
- SF
- MF
Specification | Objective |
---|---|
Select insulation that is rated for ground contact and is a class I vapor retarder |
Durable insulation selected |
- SF
- MF
Specification | Objective |
---|---|
Select sealants that: are compatible with their intended surfaces allow for differential expansion and contraction between dissimilar materials meet the requirements of the applicable fire safety code (e.g., thermal or ignition barriers) are low volatile organic compound (VOC) sealants for use inside the pressure boundary that meet independent testing and verification protocols |
Select safe and effective sealants |
- SF
- MF
Specification | Objective |
---|---|
Prepare slab edge to receive insulation and/or sealing materials per manufacturer specifications |
Surface ready for insulation and sealant |
- SF
- MF
Specification | Objective |
---|---|
Excavate slab edge to prescribed depth and width for installation while avoiding undermining slab footing or damaging underground utilities or drainage Protect excavation from weather until restored to original condition (e.g., density, drainage function) |
Provide installation access and protect slab and utilities from damage |
- SF
- MF
Specification | Objective |
---|---|
Install insulation to prescribed R-value in contact with the slab edge, without voids, compressions, or misalignments and tight to any utilities penetrating the slab edge insulation |
Continuous and contiguous thermal boundary |
- SF
- MF
Specification | Objective |
---|---|
Install continuous and permanent flashing to direct water away from the foundation and slab edge insulation |
Direct bulk moisture away from slab insulation |
- SF
- MF
Specification | Objective |
---|---|
Cover exposed insulation with a durable, rigid, and pest-resistant material |
Protect insulation from weather and impact |
- SF
- MF
Specification | Objective |
---|---|
Seal all slab edge penetrations using a compatible sealant Stuff any gaps 1/4" or greater with copper or stainless steel mesh prior to sealant application |
Airtight and pest-resistant slab edge |
- SF
- MF
Specification | Objective |
---|---|
Preserve existing termite treatment and inspection gaps as required by applicable codes |
Prevent pest entry and maintain applicable warranties |
- SF
- MF
Specification | Objective |
---|---|
Restore excavated earth and grade to drain bulk moisture away from foundation |
Preserve the drainage plane of the slab edge |
- SF
- MF
Specification | Objective |
---|---|
Post a dated receipt signed by the installer that minimally includes: Installed insulation type, coverage area, installed thickness, and installed R-value |