Adequate hot water supplied by a leak free, safe, durable, efficient, and accessible water heater
Specifications
- SF
- MH
- MF
Specification | Objective |
---|---|
Verify current plumbing infrastructure is sufficient to support the installation(s) and is leak-free |
Verify adequacy of plumbing |
- SF
- MH
- MF
Specification | Objective |
---|---|
Select a water heater that: is ENERGY STAR® certified, equivalent, or better fits in the installation space with required clearances provides sufficient hot water for the home and occupants |
Select efficient and properly sized water heater |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install appliance where it: is protected from freezing is accessible for service will minimize distance between tank and primary hot water outlets |
Select freeze protected, safe, efficient and accessible location |
- SF
- MH
- MF
Specification | Objective |
---|---|
Provide a level working space not less than 30" in length and 30" in width in front of the control side of the appliance Install appliance and plumbing to allow for inspection, maintenance, and replacement of the appliance and its components, without disturbing other installed equipment, controls, piping, and components, other than what requires repair/replacement |
Ensure the appliance can be easily maintained and replaced |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install a separate water cut-off valve for both the hot and cold water lines |
Allow isolation of tank |
- SF
- MH
- MF
Specification | Objective |
---|---|
Direct scalding water away from occupants |
- SF
- MH
- MF
Specification | Objective |
---|---|
Safe and effective fuel delivery that provides for emergency fuel cut-off |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install dielectric unions when connecting copper to galvanized steel piping in accordance with the IRC and manufacturer specifications |
Prevent corrosion between dissimilar metals |
- SF
- MH
- MF
Specification | Objective |
---|---|
Set discharge temperature to not exceed 120 degrees or as prescribed by local code |
Prevent biological growth in tank but prevent scalding |
- SF
- MH
- MF
Specification | Objective |
---|---|
Permanently remove equipment from job site and recycle or dispose of removed equipment and refrigerant in accordance with local and federal law (e.g., EPA Section 608 of Clean Air Act of 1990) Permanently decommission old equipment |
Old equipment is permanently removed from service, protect the environment, and comply with regulation |
- SF
- MH
- MF
Specification | Objective |
---|---|
Provide occupants/owners with user's manual, warranty information, installation instructions, and installer contact information |
Manufacturer supplied information available to occupant |